Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi OKI C3300n

Code: 001

Display:
Description: Machine Check Exception Hardware fault detected. (Board defectiveness or Shortage of power supply volume)
Remedy: Replace TB3 board

Code: 002 ... 007

Display: Service call 002: Error 005: Error
Description: CPU Excepption
Remedy: Is the error message displayed again?
If the RAM DIMM is mounted, remove it and turn the power supply off/ON. Replace TB3 board Remount RAM DIMM Replace RAMDIMM

Code: 020

Display: Service call 020:Error
Description: CU ROM Hash Check Error
Remedy: Does error display reappear? Power OFF/ON Replace TB3 board

Code: 025

Display: Service call 025:Error
Description: CU Font ROM Hash Check Error
Remedy: A font ROM hash check error was detected. (On printers for domestic market only) Power OFF/ON Replace TB3 board

Code: 030

Display: Service call 030: Error
Description: CU RAM Check Error
Remedy: Is the error message displayed again?
Power supply OFF/ON Replace TB3 board

Code: 031

Display: Service call 031: Error
Description: CU Optical RAM Check Error
Remedy: Is RAM DIMM installed properly? Does it restore by exchanging RAM DIMM?
Remount RAM DIMM Replace RAMDIMM Replace TB3 board

Code: 036

Display: Service call 036:Error
Description: RAM Spec Error Unsupported DIMM specification of the CU RAM
Remedy: Is a genuine RAM DIMM in use? Is the RAM DIMM installed properly? Is the fault recovered when the RAM DIMM is replaced?
Use genuine RAM DIMM. Reset RAM DIMM. Replace RAM DIMM. Replace TB3 board

Code: 040

Display: Service call 040: Error
Description: CU EEPROM Error
Remedy: Is the error message displayed again? Power supply OFF/ON Replace TB3 board