Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi OKI C3300n — Trang 5/7

Code: 169

Display: Service call 169: Error
Description: Upper Side Thermistor Error
Remedy: Is the error message displayed? Does the error recur?
Turn on the power supply again Turn on the power supply again after storage for 30 minutes.

Code: 170, 171

Display: Service call 170: Error 171: Error
Description: Thermistor Short circuit / Open circuit of the fuser is detected
Remedy: Check the cable connection between the ZAK board and TB3 board and turn on the power again. Replace the fuser unit. Replace the TB3 board.

Code: 172, 173

Display: Service call 172: Error 173: Error
Description: Thermistor Temperature abnormality (high or low) of the fuser is detected
Remedy: Check the cable connection between the ZAK board and TB3 board and turn on the power again. Replace the fuser unit. Replace the TB3 board.

Code: 174

Display: Service call 174: Error
Description: The short circuit of the backup roller Thermistor is detected. (For the high temperature)
Remedy: Check the cable connection between the ZAK board and TB3 board and turn on the power again. Replace the fuser unit. Replace the TB3 board.

Code: 175

Display: Service call 175: Error
Description: The open circuit of the backup roller Thermistor is detected. (For the low temperature)
Remedy: Check the cable connection between the ZAK board and TB3 board and turn on the power again. Replace the fuser unit. Replace the TB3 board.

Code: 176, 177

Display: Service call 176: Error 177: Error
Description: Temperature abnormality (high or low) of the backup Laura thermistor was detected
Remedy: Check the cable connection between the ZAK board and TB3 board and turn on the power again. Replace the fuser unit. Replace the TB3 board.

Code: 190

Display: Service call 190: Error
Description: System memory overflow
Remedy: Turn on the power supply again. Install an additional RAM DIMM.

Code: 200 ... 202

Display: Service call 200: Error 202: Error
Description: PU Firmware Download Error
Error occurs when the PU firmware is rewritten
Remedy: After the power supply is turned on again, try to download again. (Because this processing is not performed during usual operation, it does not occur.)