Mã lỗi OKI C3400 — Trang 2/7
Code:
Tất cả lỗi (53)
001
002 ... 007
020
025
030
031
036
040
042, 043, 045
052
070
072
073
074, 075
081
104
106
120
121
122
123
124
126
127
131 ... 134
140
150 ... 153
154
155
160 ... 163
167
168
169
170, 171
172, 173
174
175
176, 177
190
200 ... 202
203 ... 214
209
230
231
240
901, 902
903, 904
923
980
983
<table border="1" cellpadding="3" cellspacing="1"> <tr class="H2"> Code</li>
<li><span cl
FFF
FOC
Display: Service call 042: Error 043: Error
Description: Flash File System Error It failed to the access to CU Flash ROM that is attached to the BLA board directly.
Remedy: Replace TB3 board
Display: Power off/on 052:Error
Description: DMA Abort Error detected in Image processor.
Remedy: Does error reoccur? Power OFF/ON. Replace TB3 board.
Display: Power off/on 070:Error
Description: PSE firmware fault detected.
Remedy: Does error reoccur? Power OFF/ON. Replace TB3 board.
Display: Service call 072: Error
Description: Engine I/F Error I/F Error between PU and CU
Remedy: Replace TB3 board
Display: Service call 073: Error
Description: Video Error When the image data sprads, defect is detected. (Incorrect data receive)
Remedy: Does the error recur? Change the PC to high spec or lower the resolution, and then print again. Replace TB3 board
Display: Service call 074: Error 075: Error
Description: Video Error When the image data spreads, defect is detected.
Remedy: Replace TB3 board
Display: Service call 081: Error
Description: Difference between version of CU firm and EEPROM
Remedy: Do EEPROM Initialization. (Turn on the power supply by Coveropen & pressing ONLINE switch & pressing CANCEL switch). Because the Mac address will disappear with this initialization, please reset Mac address by using the maintenance utility. Replace TB3 board
Display: Service call 104: Error
Description: Engine EEPROM mounting check is OK with turning on the power supply, after that, lead/ light error is detected
Remedy: Power supply OFF/ON Replace TB3 board