Remedy: Dew condensation occurs easily after the device is carried in from outside. After leaving it at room temperature for 2 hours to half a day, turn on the power again. Does the error recur? Yes Turn on the power again after leaving the device for hours. Replace the high-voltage power supply.
Code: 127
Display: Service call 127: Error
Description: Fixed cooling fan error
Remedy: Is the connector connection of the fan normal? Does the error recur? Reconnect normally Replace the fan motor
Code: 131 ... 134
Display: Service call 131: Error - 134: Error
Description: LED head detection abnormality (131=Y, 132=M, 133=C, 134=K)
Remedy: Is the LED head installed correctly? Does LED HEAD FUSE cut? Does the error recur? Install the LED head correctly Check LED HEAD FUSE Replace FUSE Turn on the power supply gain Replace the LED head unit Please refer to chapter 7.6 for replace method of FUSE Replace M32 board
Code: 140 ... 142
Display: Service call 140: Error - 142: Error
Description: ID Up/Down position detection error
Remedy: Does it has anything trouble with the detaching/attaching of ID unit? Does the error recur? Reinstall the ID unit Turn on the power supply again Replace the high voltage power supply
Code: 150 ... 153
Display: Service call 150: Error - 153: Error
Description: Defective fuse cutting of ID unit
Remedy: Is the ID unit installed correctly? Does the error reoacur? Does it restore by exchanging PRE board Installed ID unit again Turn on the power supply again Replace PRE board after check the cable connection of PRE board-M32 board. Replace M32 board.
Code: 154
Display: Service call 154: Error
Description: Defective fuse cutting of belt unit
Remedy: Is the belt unit installed correctly? Does the error recur? Reinstall the belt unit. Turn on the power supply again. Replace M32 board after check cable connection.
Code: 155
Display: Service call 155: Error
Description: Defective fuse cutting of fuser
Remedy: Is the fuser installed correctly? Does the error recur? Reinstall the fuser after its connection connector is cleaned Turn on the power supply again Replace M32 board after check the cable connection.
Code: 160 ... 163
Display: Service call 160: Error - 163: Error
Description: Defective toner sensor detection. It does not occur during shipping setting
Remedy: Is the toner cartridge installed? Is the lock level of toner set? Does the error recur? Does the error recur? Does the error recur? Install a toner cartridge. Turn the lock lever of toner cartridge to the fixed position. Remove the right side cover, take measures to prevent the right side of the device from being exposed to ambient light, and confirm that the toner sensor is lighted during initialization of the device. Reconfirm it after replacing the toner sensor Assy. Replace the M32 board.