Các lỗi thường gặp

Code :
  • Code: 074, 075
  • Display: Service call 074: Error 075: Error
  • Description: Video Error When the image data spreads, defect is detected.
  • Remedy: Replace M32 board
  • Code: 081
  • Display: Service call 081: Error
  • Description: Difference between version of CU firm and EEPROM
  • Remedy: Does the error recur? Yes Do EEPROM Initialization. (Turn on the power supply by Cover-open & pressing START key & pressing CANCEL switch). Because the Mac address will disappear with this initialization, lease reset Mac address by using the maintenance utility. Replace M32 board
  • Code: 104
  • Display: Service call 104: Error
  • Description: EngineEEPROM mounting check is OK with turning on the power supply, after that, lead/light error is detected
  • Remedy: Does the error recur? Yes Power supply OFF/ON Replace M32 board
  • Code: 105
  • Display: Service call 105: Error
  • Description: Engine EEPROM mounting check error when the power supply is turned on.
  • Remedy: Does the error recur? Yes Power supply OFF/ON Replace M32 board
  • Code: 106
  • Display: Service call 106: Error
  • Description: The engine control logic is abnormal
  • Remedy: Does the error recur? Yes Power supply OFF/ON Replace M32 board
  • Code: 121
  • Display: Service call 121: Error
  • Description: High-voltage power supply I/F error
  • Remedy: Is the cable between PU board ant the high-voltage power supply unit correctly connected? Isn't there defective contact point?
    Reconnect correctly. Check the defective contact point of high-voltage system. Replace the high voltage power supply.
  • Code: 123
  • Display: Service call 123: Error
  • Description: Environmental humidity abnormal/ humidity sensor disconnection
  • Remedy: Is the cable between the PU board and the high-voltage power supply unit correctly connected?
    Reconnect correctly. Replace the high-voltage power supply.
  • Code: 124
  • Display: Service call 124: Error
  • Description: Environmental temperature abnormality
  • Remedy: Does the error recur? Yes Power supply OFF/ON Replace control panel board (PRP)