Description: Video Error When the image data spreads, defect is detected.
Remedy: Replace M32 board
Code: 081
Display: Service call 081: Error
Description: Difference between version of CU firm and EEPROM
Remedy: Does the error recur? Yes Do EEPROM Initialization. (Turn on the power supply by Cover-open & pressing START key & pressing CANCEL switch). Because the Mac address will disappear with this initialization, lease reset Mac address by using the maintenance utility. Replace M32 board
Code: 104
Display: Service call 104: Error
Description: EngineEEPROM mounting check is OK with turning on the power supply, after that, lead/light error is detected
Remedy: Does the error recur? Yes Power supply OFF/ON Replace M32 board
Code: 105
Display: Service call 105: Error
Description: Engine EEPROM mounting check error when the power supply is turned on.
Remedy: Does the error recur? Yes Power supply OFF/ON Replace M32 board
Code: 106
Display: Service call 106: Error
Description: The engine control logic is abnormal
Remedy: Does the error recur? Yes Power supply OFF/ON Replace M32 board
Code: 121
Display: Service call 121: Error
Description: High-voltage power supply I/F error
Remedy: Is the cable between PU board ant the high-voltage power supply unit correctly connected? Isn't there defective contact point? Reconnect correctly. Check the defective contact point of high-voltage system. Replace the high voltage power supply.
Remedy: Is the cable between the PU board and the high-voltage power supply unit correctly connected? Reconnect correctly. Replace the high-voltage power supply.
Code: 124
Display: Service call 124: Error
Description: Environmental temperature abnormality
Remedy: Does the error recur? Yes Power supply OFF/ON Replace control panel board (PRP)