Các lỗi thường gặp

Code :
  • Code: 906
  • Display: Service call 906:Error
  • Description: A short circuit error of frame thermistor (defective improper) detected.
  • Remedy: Does error reoccur? Turn power ON again. Replace the fuser unit.
  • Code: 907
  • Display: Service call 907:Error
  • Description: A high temperature error (over 150°C) of frame thermistor detected.
  • Remedy: Does error reoccur? Turn power ON again. Replace the fuser unit.
  • Code: 908
  • Display: Service call 908:Error
  • Description: A low temperature error (below [environmental temperature minus 10]°C) of frame thermistor detected.
  • Remedy: Does error reoccur? Turn power ON again. Replace the fuser unit.
  • Code: FOC, F0D, FFE, FFF
  • Display: Power off/on 203:Error
    204:Error 207:Error
    208:Error 210:Error ~ 214:Error
    F0C:Error F0D:Error(C5400 only)
    FFE:Error(C5400 only) FFF:Error
  • Description: An error was detected of the CU program. (203~214 is not occure in usual operating.)
  • Remedy: Reinstall the CU board. Is the error message displayed again? After turn power OFF, check connections between CU board and PU board. Then turn power ON again.