Code: 072

Display: Power off/on 072:Error xx
Description: Engine I/F Error I/F error between PU-CU.
Remedy: Is CU assembly set properly? Is error recovered by replacing ARC/SPA board?
Set properly. Replace ARC/SPA board. Replace PU board (PRN)

Code: 073

Display: Power off/on 073:Error xxxxxxxx
Description: Video Error Fault detected when image data is extended.
Remedy: [C5200] Is CU assembly set properly? Fault again?
Set properly. Replace to highperformance PC or drop resolution of data and print again. Replace ARC board
[C5400] Is CU assembly set properly? Set properly. Replace SPA board.

Code: 074

Display: Power off/on 074:Error xxxxxxxx
075:Error xxxxxxxx
Description: Video Error Fault detected when image data is extended.
Remedy: Is CU assembly set properly? Set properly. Replace ARC/SPA board.

Code: 104

Display: Service call 104:Error
Description: Engine EEPROM setting check is OK when power ON. Then detect read/ write error.
Remedy: Does error reoccur? Power OFF/ON Replace PU board (PRN)

Code: 105

Display: Service call 105:Error
Description: An error detected by checking, at printer's power-om, EEPROM installation.
Remedy: Does error reoccur? Power OFF/ON Replace PU board (PRN)

Code: 106

Display: Service call 106:Error
Description: Abnormal engine control logic.
Remedy: Does error reoccur? Power OFF/ON Replace PU board (PRN)

Code: 121

Display: Service call 121:Error
Description: High-voltage power supply I/F error.
Remedy: Is cable between PU board and high-voltage power unit connected properly? Is there no improperly connections?
Connect properly. Check improper connections for high-voltage. Replace high-voltage power supply.

Code: 122

Display: Service call 122:Error
Description: Low-voltage power supply fan error. Low-voltage power supply temperature error.
Remedy: Is fan in low-voltage power supply unit operating? Is fan connector connected properly?
Check connections for connector of fan. Replace low-voltage power supply. Replace fan motor. Replace low-voltage power supply.