Mã lỗi OKI C5400n — Trang 3/8
Display: Service call 035:Error(C5400)
Description: CU Optional RAM Spec Error CU RAM DIMM is not adjust to the specification.
Causes: Is RAM DIMM genuin? Is RAM DIMM set properly? Is error recovered by replacing RAM DIMM?
Display: Service call 040:Error
Description: CU EEPROM Error
Causes: Does error display reappear?
Display: Service call 041:Error
Description: CU Flash Error Flash ROM Error on the CU board.
Causes: Does error display reappear?
Display: Service call 042:Error ~ 044:Error
Description: Flash File System Error
Causes: Failed access to Flash set directly on CU board.
Display: Service call 051:Error(C5400)
Description: CU Fan Error Abnormal CPU cooling fan on CU board.
Causes: Is CU Fan connector set properly? Is error recovered by replacing fan?
Display: Service call 052:Error(C5400)
Description: DMA Abort Error detected in Image processor.
Causes: Does error reoccur?
Display: Power off/on 070:Error(C5400)
Description: PSE firmware fault detected.
Causes: Does error reoccur?
Display: Power off/on 072:Error xx
Description: Engine I/F Error I/F error between PU-CU.
Causes: Is CU assembly set properly? Is error recovered by replacing ARC/SPY/SPA board?