Các lỗi thường gặp

Code :
  • Code: 112
  • Display: Service call 112:Error
  • Description: Detected illegal 2nd Tray.
  • Causes: Is 2nd Tray of C5300/C5100 installed?
  • Code: 120
  • Display: Service call 120: ERROR
  • Description: PU unit FAN motor error
  • Causes: 1) Is the FAN in the PU unit working? 2) Does the same error occur after replacement of the FAN motor?
  • Code: 121
  • Display: Service call 121:Error
  • Description: High-voltage power supply I/F error.
  • Causes: Is cable between PU PCB and highvoltage power unit connected properly? Is there no improperly connections?
  • Code: 122
  • Display: Service call 122:Error
  • Description: Low-voltage power supply fan error. Low-voltage power supply temperature error.
  • Causes: Is fan in low-voltage power supply unit operating? Is fan connector connected properly?
  • Code: 123
  • Display: Service call 123:Error
  • Description: Abnormal environment humidty /Not connected humidity sensor
  • Causes: Does error reoccur?
  • Code: 124
  • Display: Service call 124:Error
  • Description: Abnormal environment temperature.
  • Causes: Does error reoccur?
  • Code: 126
  • Display: Power off/on 126:Error
  • Description: Condensation in the printer was detected.
  • Causes: Condensation iss likely to occur in printers carried from the outside. Turn on the printer again after it is exposed to room temperature for two hours to half a day. Does the error reoccur?
  • Code: 127
  • Display: Service call 127:Error
  • Description: Error detected at the fuser unit cooling fan.
  • Causes: Is fan connector connected properly? Does error reoccur?