Code :
Tất cả lỗi
-01 -02 -03 -04 -05 001 002 ... 007 020 025 030 031 036 040 041 042 ... 045 052 070 072 073 074, 075 081 104 106 111 112 120 121 122 123 124 126 127 131 ... 134 142 150 ... 153 154 155 160 ... 163 167 168 169 170, 171 172, 173 174 175 176, 177 181, 182 190 200 ... 202 203 ... 214 209 220 230 231 241 242 250 251 901, 902 903, 904 918 923 928 980 F0C, F0D, FFF
Code: 112
Display: Service call 112:Error
Description: Detected illegal 2nd Tray. Causes: Is 2nd Tray of C5300/C5100 installed?
Code: 120
Display: Service call 120: ERROR
Description: PU unit FAN motor error Causes: 1) Is the FAN in the PU unit working? 2) Does the same error occur after replacement of the FAN motor?
Code: 121
Display: Service call 121:Error
Description: High-voltage power supply I/F error. Causes: Is cable between PU PCB and highvoltage power unit connected properly? Is there no improperly connections?
Code: 122
Display: Service call 122:Error
Description: Low-voltage power supply fan error. Low-voltage power supply temperature error. Causes: Is fan in low-voltage power supply unit operating? Is fan connector connected properly?
Code: 123
Display: Service call 123:Error
Description: Abnormal environment humidty /Not connected humidity sensor Causes: Does error reoccur?
Code: 124
Display: Service call 124:Error
Description: Abnormal environment temperature. Causes: Does error reoccur?
Code: 126
Display: Power off/on 126:Error
Description: Condensation in the printer was detected. Causes: Condensation iss likely to occur in printers carried from the outside. Turn on the printer again after it is exposed to room temperature for two hours to half a day. Does the error reoccur?
Code: 127
Display: Service call 127:Error
Description: Error detected at the fuser unit cooling fan. Causes: Is fan connector connected properly? Does error reoccur?