Display: Power off/on 070:Error
Description: PSE firmware fault detected.
Causes: Does error reoccur?
Display: Power off/on 072:Error xx
Description: Engine I/F Error I/F error between PU-CU.
Causes: Is CU assembly set properly? Is error recovered by replacing CU PCB?
Display: Power off/on 073:Error xxxxxxxx
Description: Video Error. A trouble was detected during image data development. (Illegal data received)
Causes: [On the C5650] Is the CU Assy installed properly? Is the error issued again?
[On the C6050/C6150] Is the CU Assy installed properly?
[Common]
Display: Power off/on 074:Error xxxxxxxx 075:Error xxxxxxxx
Description: Video Error Fault detected when image data is extended.
Causes: Is CU assembly set properly?
Display: Service call 081: ERROR
Description: Parameterconsistency check error
Causes: EEPROM or FLASH has become incapable of reading or writing.
Display: Service call 104:Error
Description: Engine EEPROM setting check is OK when power ON. Then detect read/ write error.
Causes: Does error reoccur?
Display: Service call 106:Error
Description: Abnormal engine control logic.
Causes: Does error reoccur?
Display: Service call 111:Error
Description: Detected illegal Duplex Unit.
Causes: Is Duplex Unit of C5300/C5100 installed?