Code: 112

Display: Service call 112:Error
Description: Detected illegal 2nd Tray.
Causes: Is 2nd Tray of C5300/C5100 installed?

Code: 120

Display: Service call 120: ERROR
Description: PU unit FAN motor error
Causes: 1) Is the FAN in the PU unit working? 2) Does the same error occur after replacement of the FAN motor?

Code: 121

Display: Service call 121:Error
Description: High-voltage power supply I/F error.
Causes: Is cable between PU PCB and highvoltage power unit connected properly? Is there no improperly connections?

Code: 122

Display: Service call 122:Error
Description: Low-voltage power supply fan error. Low-voltage power supply temperature error.
Causes: Is fan in low-voltage power supply unit operating? Is fan connector connected properly?

Code: 123

Display: Service call 123:Error
Description: Abnormal environment humidty /Not connected humidity sensor
Causes: Does error reoccur?

Code: 124

Display: Service call 124:Error
Description: Abnormal environment temperature.
Causes: Does error reoccur?

Code: 126

Display: Power off/on 126:Error
Description: Condensation in the printer was detected.
Causes: Condensation iss likely to occur in printers carried from the outside. Turn on the printer again after it is exposed to room temperature for two hours to half a day. Does the error reoccur?

Code: 127

Display: Service call 127:Error
Description: Error detected at the fuser unit cooling fan.
Causes: Is fan connector connected properly? Does error reoccur?