Description: Abnormal temperature detected by fuser thermistor (hightemp or low temp.)
Remedy: Does error reoccur? Turn power ON again. Replace fuser unit. Replace the low-voltage power supply.
Code: 174
Display: SERVICE CALL 174:Error
Description: Short circuit in back up roller thermistor detected (at high temperature).
Remedy: Does error reoccur? Yes Turn power ON again. Replace fuser unit.
Code: 175
Display: SERVICE CALL 175:Error
Description: Open of back up roller thermistor detected (at low temperature).
Remedy: Does error reoccur? Yes Turn power ON again. Replace fuser unit.
Code: 176, 177
Display: SERVICE CALL 176:Error 177:Error
Description: Abnormal (high) temperature of back up roller thermistor detected.
Remedy: Does error reoccur? Turn power ON again. Replace fuser unit. Replace the low-voltage power supply.
Code: 181, 182
Display: SERVICE CALL 181:Error 182:Error
Description: Option unit I/F error. (181 = Duplex Unit, 182 = Option Tray)
Remedy: Does error reoccur? Yes Turn power ON again. After checking connection parts of connector, replace option unit.
Code: 190
Display: POWER OFF/ON 190:Error
Description: System Memory Overflow.
Remedy: Does error reoccur? Yes Turn power ON again. Add option RAM DIMM.
Code: 200, 201, 202
Display: SERVICE CALL 200:Error ~ 202:Error
Description: PU Firmware download Error. Error occurered while writing over the PU firmware.
Remedy: Error occurered while writing over the PU firmware. Turn the printer OFF/ON, and retry to download the PU firmware again. (Usually, the procedure (PU firmware download) which isn’t done, so this is not occur.)
Code: 203, 204, 207, 208, 214, F0C, FFF
Display: POWER OFF/ON 203:Error 204:Error 207:Error 208:Error 214:Error F0C:Error FFF:Error
Description: An error was detected of the CU program. (203~214 is not occure in usual operating.)
Remedy: Reinstall the CU board. Is the error message displayed again? After turn power OFF, check connections between CU board and PU board. Then turn power ON again.