Mã lỗi OKI C9850 — Trang 10/11

Code: 926

Display: Power Off/on 926: Error
Description: Tray4 24V Abnormal Voltage Detection
24 V power is not supplied to tray 4 properly.
Remedy: 24 V power is not supplied to tray 4 properly. Check to confirm that tray 4 is mounted correctly.

Code: 927

Display: Power Off/on 927: Error
Description: Tray5 24V Abnormal Voltage Detection
24 V of power is not supplied to tray 5 properly.
Remedy: 24 V of power is not supplied to tray 5 properly. Check to confirm that tray 5 is mounted correctly.

Code: 928

Display: Power Off/on 928: Error
Description: Fuser Motor Lock Error
The fuser is not operating properly.
Remedy: The fuser is not operating properly. Does the error still occur?
Check to confirm that the fuser is in position. Replace the fuser. Replace the fuser motor.

Code: 929

Display: Power Off/on 929: Error
Description: Waste Toner Transfer Motor Lock Error
The waste toner transfer motor is not operating properly.
Remedy: The waste toner transfer motor is not operating properly. Does the error still occur? Yes Check to confirm that the waste toner transfer system is operating properly. Replace the waste toner motor.

Code: 930

Display: Power Off/on 930: Error
Description: Sub-CPU Clock Frequency Error
The Sub-CPU clock frequency is not correct.
Remedy: The Sub-CPU clock frequency is not correct. Does the error still occur? Yes Check the connection of the S2P board. Replace the S2P board.

Code: 931

Display: Power Off/on 931: Error
Description: Duplex CPU Clock Frequency Error
Remedy: The duplex CPU clock frequency is not correct.Does the error still occur? Yes Check the connection of the V72-2 board. Replace the V72-2 board.

Code: 932

Display: Power Off/on 932: Error
Description: Inverter CPU Clock Frequency Error
Remedy: The inverter CPU clock frequency is not correct. Does the error still occur? Yes Check the connection of the V72-3 board. Replace the V72-3 board.

Code: 933

Display: Power Off/on 933: Error
Description: Trya2 CPU Clock Frequency Error
Remedy: The tray-2 CPU clock frequency is not correct. Does the error still occur? Yes Check the connection of the V72-1 board of tray 2. Replace the V72-1 board.