Các lỗi thường gặp

Code :
  • Code: 934
  • Display: Power Off/on 934: Error
  • Description: Trya3 CPU Clock Frequency Error
  • Remedy: The tray-3 CPU clock frequency is not correct. Does the error still occur? Yes Check the connection of the V72-1 board of tray 3. Replace the V72-1 board.
  • Code: 935
  • Display: Power Off/on 935: Error
  • Description: Trya4 CPU Clock Frequency Error
  • Remedy: The tray-4 CPU clock frequency is not correct. Does the error still occur? Yes Check the connection of the V72-1 board of tray 4. Replace the V72-1 board.
  • Code: 936
  • Display: Power Off/on 936: Error
  • Description: Trya5 CPU Clock Frequency Error
  • Remedy: The tray-5 CPU clock frequency is not correct. Does the error still occur? Yes Check the connection of the V72-1 board of tray 5. Replace the V72-1 board.
  • Code: 940
  • Display: Power Off/on 940: Error
  • Description: Waste Toner Transfer Error
    The transfer mechanism of the toner duct for ID is not operating properly.
  • Remedy: The transfer mechanism of the toner duct for ID is not operating properly. Does the error still occur?
    Check to confirm that the basket assembly is in position (if it is engaged with the gear of the printer). Check to confirm that the holder magnet D contains a magnet, and check the magnetic polarity. Replace the HAL IC circuit board. Replace the duct assembly toner.
  • Code: F0C, F0D, FFE, FFF
  • Display: Service Call 203: Error 204: Error 207: Error to 214: Error Power Off/on nnn: p 0xFOC: Error 0xFOD: Error 0xFFE: Error 0xFFF: Error
  • Description: CU Program Dysfunction
    Detected illegal process with CU program.
  • Remedy: Detected illegal process with CU program. Yes Write down the 24 digit number displayed on the LCD panel and report it. Turn OFF the power. Then check the insertion of the CU board. Now turn ON the power again.