Description: SRAM/NVRAM abnormality on the SYS board
Remedy: (1) Turn the power OFF and start up the Setting Mode (08). (2) When the message “NVRAM/SRAM ERROR DOES IT INITIALIZE?” is displayed on the LCD, press the [INTERRUPT] or [INITIALIZE] button. (SRAM is cleared and NVRAM is initialized.) (3) Perform the panel calibration (08-692). Note: When the NVRAM is initialized, the scanner and image processing related adjustments are also initialized. Readjust them after the NVRAM initialization. (4) Turn the power OFF and then back ON. If the error is not recovered, replace the NVRAM on the SYS board.
Code: F100
Description: HDD format error
Remedy: (1) Check if the HDD is mounted. (2) Check if the specified HDD is mounted. (3) Check if the connector pins of the HDD are bent. (4) Check if the connectors CN112, CN113 on the SYS board is disconnected. (5) Replace the harness. (6) Format the HDD. (Key in "2" at 08-690.) (7) Replace the HDD. (8) Replace the SYS board.
Code: F101 ... F105
Description: [F101] HDD unmounted [F102] HDD start error [F103] HDD transfer time-out [F104] HDD data error [F105] HDD other error
Remedy: (1) Check if the connectors of the HDD are disconnected. (2) Check if the connector pins are disconnected or the wires of harnesses are open circuited. (3) Perform the bad sector check (08-694). If the check result is OK, recover the data in the HDD. If the check result is failed, replace the HDD. (4) Replace the SYS board.
Code: F106
Description: Point and Print partition damage
Remedy: (1) Turn the power OFF and start up the Setting Mode (08). (2) Key in “662” and press the [START] button. (Partition clearing is performed.) (3) Restart the equipment. (4) Access TopAccess. Click the [Administration] tab, and then click the Maintenance Menu to open. Then install the “Point and Print” driver.
Code: F107
Description: SHR partition damage
Remedy: Initialize the Electronic Filing using the Setting Mode (08-666).
Code: F108
Description: SHA partition damage
Remedy: Initialize the shared folder using the Setting Mode (08-667).
Code: F110, F111
Description: [F110] Communication error between System-CPU and Scanner-CPU [F111] Scanner response abnormality
Remedy: (1) Check if the harness connecting the SYS board and SLG board is disconnected or open circuited. (2) Check the version of the system ROM on the SYS board. (3) Check the version of the scanner ROM version on the SLG board. (4) Replace the SYS board. (5) Replace the SLG board.
Code: F120
Description: Database abnormality
Remedy: (1) Rebuild the databases. (Perform 08-684.) (2) If the error is not recovered, initialize the HDD. (Key in “2” at 08-690.) * When “Rebuilding all databases (08-684)” is performed, all data in the Address Book and Mailbox are deleted. Make sure to back up these data in advance of rebuilding and restore the data after rebuilding.