Code :
  • Code: 106
  • Display: Service call 106:Error
  • Description: Abnormal engine control logic.
  • Remedy: Does error reoccur? Yes Power OFF/ON Replace PU PCB (PRF)
  • Code: 111
  • Display: Service call 111:Error
  • Description: Detected illegal Duplex Unit.
  • Remedy: Is Duplex Unit of C5300/C5100 installed? Yes Install Duplex Unit of MC560.
  • Code: 112
  • Display: Service call 112:Error
  • Description: Detected illegal 2nd Tray.
  • Remedy: Is 2nd Tray of C5300/C5100 installed? Yes Install 2nd Tray of MC560.
  • Code: 120
  • Display: Service call 120: ERROR
  • Description: PU unit FAN motor error
  • Remedy: 1) Is the FAN in the PU unit working? 2) Does the same error occur after replacement of the FAN motor?
    Replace the FAN motor. Replace the PU board (PRF). Replace the PU board (PRF).
  • Code: 121
  • Display: Service call 121:Error
  • Description: High-voltage power supply I/F error.
  • Remedy: Is cable between PU board and high-voltage power unit connected properly? Is there no improperly connections?
    Connect properly. Check improper connections for highvoltage. Replace high-voltage power supply.
  • Code: 122
  • Display: Service call 122:Error
  • Description: Low-voltage power supply fan error. Low-voltage power supply temperature error.
  • Remedy: Is fan in low-voltage power supply unit operating? Is fan connector connected properly?
    Check connections for connector of fan. Replace low-voltage power supply. Replace fan motor. Replace low-voltage power supply.
  • Code: 123
  • Display: Service call 123:Error
  • Description: Abnormal environment humidity / Not connected humidity sensor.
  • Remedy: Does error reoccur? Yes Power OFF/ON Replace the operator panel PCB (PRP)
  • Code: 124
  • Display: Service call 124:Error
  • Description: Abnormal environment temperature.
  • Remedy: Does error reoccur? Yes Power OFF/ON Replace the operator panel PCB(PRF)