Các lỗi thường gặp

Code :
  • Code: 142
  • Display: Service call 142:Error
  • Description: Error detented at ID position of Up/ Down
  • Causes: Is ID unit set properly? Does error reoccur?
  • Code: 150 ... 153
  • Display: Service call 150:Error ~ 153:Error
  • Description: ID unit fuse cannot be disconnected. (150 = Y, 151 = M, 152 = C, 153 = K)
  • Causes: Is ID unit setting proper? Does error reoccur? Is error recovered by replacing PRD board?
  • Code: 154
  • Display: Service call 154:Error
  • Description: Belt unit fuse cannot be disconnected.
  • Causes: Is belt unit setting proper? Does error reoccur?
  • Code: 155
  • Display: Service call 155:Error
  • Description: Fuser unit fuse cannot be disconnected.
  • Causes: Is fuser unit set properly? Does error reoccur?
  • Code: 160 ... 163
  • Display: Service call 160:Error ~ 163:Error
  • Description: Error detected by toner sensor. (160 = Y, 161 = M, 162 = C, 163 = K) It does not occure in factory default setting.
  • Causes: Is toner cartridge setting? Is toner lock lever setting? Does error reoccur?
  • Code: 170, 171
  • Display: Service call 170:Error 171:Error
  • Description: Short circuit in fuser thermistor or open detected.
  • Causes: Does error reoccur?
  • Code: 172, 173
  • Display: Service call 172:Error 173:Error
  • Description: Abnormal temperature detected by fuser thermistor (high-temp or low temp.)
  • Causes: Does error reoccur?
  • Code: 181, 182
  • Display: Service call 181:Error 182:Error
  • Description: Option unit I/F error. (181 = Duplex Unit, 182 = Option Tray)
  • Causes: Does error reoccur?