Mã lỗi OKI ES1220 — Trang 3/5
Display: Service call 105:Error
Description: Read/ write error in the setting check of engine EEPROM when power on.
Causes: Does error reoccur?
Display: Service call 106:Error
Description: Abnormal engine control logic.
Causes: Does error reoccur?
Display: Service call 121:Error
Description: High-voltage power supply I/F error.
Causes: Is cable between PU board and high-voltage power unit connected properly? Is there no improperly connections?
Display: Service call 122:Error
Description: Low-voltage power supply fan error. Low-voltage power supply temperature error.
Causes: Is fan in low-voltage power supply unit operating? Is fan connector connected properly?
Display: Service call 123:Error
Description: Abnormal environment humidty / Not connected humidity sensor.
Causes: Does error reoccur?
Display: Service call 124:Error
Description: Abnormal environment temperature.
Causes: Does error reoccur?
Display: Service call 127:Error
Description: Error detected at the fuser unit cooling fan.
Causes: Is fan connector connected properly? Does error reoccur?
Display: Service call 131:Error ~ 134:Error
Description: LED head fault detected. (131 = Y, 132 = M, 133 = C, 134 = K)
Causes: Is LED head properly set? Does error reoccur?