Các lỗi thường gặp

Code :
  • Code: 105
  • Display: Service call 105:Error
  • Description: Read/ write error in the setting check of engine EEPROM when power on.
  • Causes: Does error reoccur?
  • Code: 106
  • Display: Service call 106:Error
  • Description: Abnormal engine control logic.
  • Causes: Does error reoccur?
  • Code: 121
  • Display: Service call 121:Error
  • Description: High-voltage power supply I/F error.
  • Causes: Is cable between PU board and high-voltage power unit connected properly? Is there no improperly connections?
  • Code: 122
  • Display: Service call 122:Error
  • Description: Low-voltage power supply fan error. Low-voltage power supply temperature error.
  • Causes: Is fan in low-voltage power supply unit operating? Is fan connector connected properly?
  • Code: 123
  • Display: Service call 123:Error
  • Description: Abnormal environment humidty / Not connected humidity sensor.
  • Causes: Does error reoccur?
  • Code: 124
  • Display: Service call 124:Error
  • Description: Abnormal environment temperature.
  • Causes: Does error reoccur?
  • Code: 127
  • Display: Service call 127:Error
  • Description: Error detected at the fuser unit cooling fan.
  • Causes: Is fan connector connected properly? Does error reoccur?
  • Code: 131 ... 134
  • Display: Service call 131:Error ~ 134:Error
  • Description: LED head fault detected. (131 = Y, 132 = M, 133 = C, 134 = K)
  • Causes: Is LED head properly set? Does error reoccur?