Remedy: Does the error occur again? Yes Turn off and on the MFP Replace the CU/PU board.
Code: 111
Description: Duplex unit for a different model was detected.
Remedy: Is Duplex unit for the model installed? No Install a correct Duplex unit.
Code: 112
Description: The 2nd tray for a model different from the MFP was detected.
Remedy: Is the 2nd tray for the MFP installed? No Install proper 2nd tray.
Code: 121
Description: High-voltage power supply interface error
Remedy: Is the cable between the CU/ PU board and the highvoltage power unit connected properly? Is a contact faulty? Reconnect it properly. Check the highvoltage line for no poor connection. Replace the highvoltage power supply.
Code: 122
Description: Rear-fan error
Remedy: Does the fan at the rear of the MFP operate? Is the connector of the fan connected properly? Be sure of the connection of the fan. Replace the CU/PU board. Connect the fan properly. Replace the CU/PU board.
Code: 123
Description: Ambient humidity error or non connection of humidity sensor
Remedy: Is the cable from the CU/PU board to the toner sensor board connected properly? Re-connect it properly. Replace the toner sensor board.
Code: 124
Description: Ambient temperature error
Remedy: Is the cable from the CU/PU board to the toner sensor board connected properly? Re-connect it properly. Replace the toner sensor board.
Code: 126
Description: Condensation on the device was detected.
Remedy: Condensation is likely to form in such a case that a device is carried in from the outdoors. Leave the device untouched for two hours to a half day and turn on the power unit. Does the error occur again? Yes Leave the device untouched and turn on the power unit. Replace a control panel board.