Description: A backup thermistor temperature error (high or low temperature) was detected.
Remedy: Does the error occur again? Turn off and on the MFP. Replace the fuser unit. Replace the lowvoltage power supply.
Code: 182
Description: Option unit I/F error
Remedy: Does the error occur again? Turn off and on the MFP. Be sure of connector connection. Replace the option unit.
Code: 190
Description: System memory overflow
Remedy: Does the error occur again? Yes Turn off and on the MFP. Replace the CU/PU board.
Code: 200, 201, 202
Description: PU firmware download error An error occurred in rewriting the PU firmware.
Remedy: An error occurred in rewriting the PU firmware. Turn off and on the MFP, and then redownload it (In general use of the MFP, this re-writing is not performed and this error does not occur).
Code: 203 ... 214
Description: CU program error (203 to 214 do not occur in general use of the MFP) Invalid processing was performed with a CU program.
Remedy: Replace the CU/PU board.
Code: 209
Description: Custom Media Type table downloading failure Custom Media Type table downloading failed.
Remedy: Turn off and on the MFP, and then redownload it (In general use of the MFP, this downloading is not performed and this error does not occur).
Code: 231
Description: TAG interface error IA TAG interface error was detected. 01 : A short-circuit error. 03 : TAG communication error.
Remedy: Be sure the toner cartridges and the image drums are properly set. Replace the toner cartridges. When the error occurs again after the image drums are re-installed, be sure of the cable connection from the CU/PU board to the toner sensor board.