Mã lỗi OKI ES3640eMFP — Trang 10/11
Display: Power Off/on 926: Error
Description: Tray4 24V Abnormal Voltage Detection
Causes: 24 V power is not supplied to tray 4 properly.
Display: Power Off/on 927: Error
Description: Tray5 24V Abnormal Voltage Detection
Causes: 24 V of power is not supplied to tray 5 properly.
Display: Power Off/on 928: Error
Description: Fuser Motor Lock Error
Causes: The fuser is not operating properly. Does the error still occur?
Display: Power Off/on 929: Error
Description: Waste Toner Transfer Motor Lock Error
Causes: The waste toner transfer motor is not operating properly. Does the error still occur?
Display: Power Off/on 930: Error
Description: Sub-CPU Clock Frequency Error
Causes: The Sub-CPU clock frequency is not correct. Does the error still occur?
Display: Power Off/on 931: Error
Description: Duplex CPU Clock Frequency Error
Causes: The duplex CPU clock frequency is not correct.Does the error still occur?
Display: 932: Error
Description: Inverter CPU Clock Frequency Error
Causes: The inverter CPU clock frequency is not correct. Does the error still occur?
Display: Power Off/on 933: Error
Description: Trya2 CPU Clock Frequency Error
Causes: The tray-2 CPU clock frequency is not correct. Does the error still occur?