Các lỗi thường gặp

Code :
  • Code: 813
  • Display: PRESS POWER SW FOR 5SEC Error : 813
  • Description: SU Communication Error
  • Causes: Communication error between the Controller and the Scanner Unit is detected.
  • Code: 923
  • Display: Power OFF/ON 923 : Error
  • Description: A lock error with black image drum
  • Causes: The image drum does not revolve properly. Does the error display is provided again by turning off and on the MFP?
  • Code: 933
  • Display: Power OFF/ON 933 : Error
  • Description: Tray-2 CPU clock frequency error
  • Causes:
  • Code: 941 ... 946
  • Display: Power OFF/ON 941 : Error 942 : Error 943 : Error 944 : Error 946 : Error
  • Description: PU Error
  • Causes: A PU error was detected. 941 : Watch Doc Timer Error 942 : Detection of Unassigned Interruption 943 : CPU Error Detection 944 : Dcon Access Error 946 : AC Voltage Zerocrossing Error
  • Code: 982
  • Display: Inspection is required. 982 : Error
  • Description: Excessive Optional Tray Detected
  • Causes:
  • Code: 984
  • Display: Inspection is required. 984 : Error
  • Description: Black Tag Version Mismatch
  • Causes:
‹ First  < 2 3 4 5