Mã lỗi OKI MB480MFP — Trang 3/8
Code:
Tất cả lỗi (60)
001
002 ... 005
006
007
020
023
024
030
031
034
040
041
042, 043
045
048
063
065
066
070
072
073
074, 075
081
104
105
106
120
121
122
123
124
126
134
153
163
167
168
169
170, 171
172, 173
174
175
176, 177
182
190
200, 201, 202
203 ... 214
209
230
231
240
905, 906
907
908
918
923
928
980
981
F0C, FFE, FFF
Display: Service call 065: Error
Description: NIC Combination Error
Remedy: Replace 86M board
Display: Service call 066: Error
Description: FAX Combination Error
Remedy: Is FX-5 board used? No use FX-5 board.
Display: Service call 070: Error
Description: PostScript Internal Error
Remedy: Is the error message displayed again? Yes Power supply Off/On Replace 86M board
Display: Service call 072: Error
Description: Engine I/F Error I/F Error between PU and CU
Remedy: Replace 86M board
Display: Service call 073: Error
Description: Video Error When the image data sprads, defect is detected. (Incorrect data receive)
Remedy: Does the error recur? Yes Change the PC to high spec or lower the resolution, and then print again. Replace 86M boar
Display: Service call 074: Error 075: Error
Description: Video Error When the image data spreads, defect is detected.
Remedy: Replace 86M board
Display: Service call 081: Error
Description: Difference between version of CU firm and EEPROM
Remedy: Does the error recur? Yes Do EEPROM Initialization. (Turn on the power supply by Cover-open & pressing START key & pressing CANCEL switch). Because the Mac address will disappear with this initialization, lease reset Mac address by using the maintenance utility. Replace 86M board
Display: Service call 104: Error
Description: EngineEEPROM mounting check is OK with turning on the power supply, after that, lead/light error is detected
Remedy: Does the error recur? Yes Power supply Off/On Replace 86M board