Code:
Tất cả lỗi (38)
002, 003, 005, FFF
030
040
042, 043
067
069
070
072
073
075
077
078
081
098
104
106
112
121
122
123
124
126
127
128
182
190
203 ... 214
209
230
231
250
251
813
923
933
941 ... 946
982
984
Display: PRESS POWER SW FOR 5SEC Error : 813
Description: SU Communication Error
Causes: Communication error between the Controller and the Scanner Unit is detected.
Display: Power OFF/ON 923 : Error
Description: A lock error with black image drum
Causes: The image drum does not revolve properly. Does the error display is provided again by turning off and on the MFP?
Display: Power OFF/ON 933 : Error
Description: Tray-2 CPU clock frequency error
Causes:
Display: Power OFF/ON 941 : Error 942 : Error 943 : Error 944 : Error 946 : Error
Description: PU Error
Causes: A PU error was detected. 941 : Watch Doc Timer Error 942 : Detection of Unassigned Interruption 943 : CPU Error Detection 944 : Dcon Access Error 946 : AC Voltage Zerocrossing Error
Display: Inspection is required. 982 : Error
Description: Excessive Optional Tray Detected
Causes:
Display: Inspection is required. 984 : Error
Description: Black Tag Version Mismatch
Causes: