Description: The backup roller thermistor is detected of its opencircuit. (At low temperature)
Remedy: Does this error recur? Yes Turn on the power again. Replace the fuser unit.
Code: C41E
Description: Compensation Thermistor Error
Remedy: Is the error message displayed? Does this error recur? Yes Turn on the power again. After leaving a printer for 30 minutes, turn on the power again.
Code: C449, C446
Description: The fuser thermistor has detected an abnormal temperature (high temperature or low temperature.)
Remedy: Does this error recur? Turn on the power again. Replace the fuser unit. Replace the low voltage power supply unit.
Code: C44A
Description: Thermistor Slope Error
Remedy: Is the error message displayed? Does this error recur? Yes Turn on the power again. After leaving a printer for 30 minutes, turn on the power again.
Code: C468, C466
Description: The backup roller thermistor has detected an abnormal temperature (high temperature or low temperature.)
Remedy: Does this error recur? Turn on the power again. Replace the fuser unit. Replace the low voltage power supply unit.
Code: C46A, C46B
Description: Compensation Heater Temp high Compensation Heater Temp Low
Remedy: Turn on the power,after 30min.
Code: C4C0
Description: The fuse has blown out.
Remedy: Is the fuser unit installed normally? Does this error recur? After cleaning the connecting connector of the fuser unit, re-install the fuser unit. Turn on the power again. After checking for the sure cable connection, replace the PU or Board IBY.
Code: C4E3
Description: Fuser motor lock error
Remedy: Fuser does not rotate normally. Does this error recur? Check if the fuser is installed normally or not. Replace the fuser. Replace the fuser motor.