Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi OKI Pro8432WT — Trang 7/11

Code: 176, 177

Display: Service call 176: Error, 177: Error
Description: An abnormal (high or low) temperature of the Lower Thermistor was detected.
Remedy: Does this error recur? Yes Restore the power. Replace the fuser unit.

Code: 181 ... 184

Display: Service call 181: Error to 184: Error
Description: Option unit I/F error (181=Duplex Unit, 182 to 184=Optional Tray)
Remedy: Does this error recur? Yes Restore the power. Check to make sure the contact points of the connector and replace the optional unit.

Code: 190

Display: Power off/on 190: Error
Description: System memory overflow
Remedy: Does this error recur? Yes Restore the power. Install an add-on RAM DIMM.

Code: 200 ... 202

Display: Service call 200: Error to 202: Error
Description: PU Firmware Download error
Remedy: An error occurred during rewriting of the PU firmware. Restore the power and retry download. (This error doesn’t occur because this process is not performed in normal operation.)

Code: 203, 204

Display: Power off/on 203: Error, 204: Error
Description: CU program error (not occur in normal operation)
The CU program executed abnormal processing.
Remedy: The CU program executed abnormal processing. Restore the power.

Code: 207, 208

Display: Power off/on 207: Error, 208: Error
Description: CU program error (not occur in normal operation)
The CU program executed abnormal processing.
Remedy: The CU program executed abnormal processing. Restore the power.

Code: 209

Display: Power off/on 209: Download Error
Description: Custom Media Type table downloading failed.
Custom Media Type table downloading failed.
Remedy: Custom Media Type table downloading failed. After turning on the power again, perform downloading again. (This error does not occur during the normal operation because this processing is not carried out in normal operation.)

Code: 213, 214

Display: Power off/on 213: Error, 214: Error
Description: CU program error (not occur in normal operation)
The CU program executed abnormal processing.
Remedy: The CU program executed abnormal processing. Restore the power.