Code :
- Code: 490
- Description: Sum of error lines exceeded the limit (Function Parameter No. 70) of 64 lines.
- Causes: Line quality is poor. SC PCB or MJR PCB are defective.
- Code: 494
- Description: Interval between two EOLs was more than 10 sec. when receiver received message data.
- Causes: Transmitter is defective. Line quality is poor. (EOL is damaged due to line noise) SC PCB or MJR PCB are defective.
- Code: 495
- Description: During reception, CD turned OFF or continued ON for long time. During communication, lost loop - current.
- Causes: Line is disconnected. Transmitter is defective. SC PCB or MJR PCB are defective.
- Code: 496
- Description: CS of modem is not able to turn ON.
- Causes: SC PCB is defective.
- Code: 501
- Description: Remote unit does not have compatible Modem.
- Causes:
- Code: 502
- Description: During reception, CD turned OFF or continued ON for long time. During communication, lost loop - current.
- Causes: Line is disconnected. Transmitter is defective. SC PCB or MJR PCB are defective.
- Code: 503
- Description: CS of modem is not able to turn ON during training.
- Causes: SC PCB is defective. Line is disconnected.
- Code: 504
- Description: Polling is rejected from the remote station.
- Causes: No polling original is set.