Code: 555

Description: Transmitted PIN after receiving EOR.
Causes: Line is faulty and Operator Call requested by RX side.

Code: 570

Description: Password or machine code did not match during remote diagnostic communication.
Causes:

Code: 571

Description: Remote unit did not have the remote diagnostic function.
Causes:

Code: 580

Description: Sub-address transmission to a unit that has their DIS bit 49 (NSF bit 155) OFF.
Causes: Sub-address transmission to a unit that has no Sub-address function.

Code: 581

Description: Sub-address Password transmission to a unit that has their DIS bit 50 (NSF bit 156) OFF.
Causes: Sub-address transmission to a unit that has no Sub-address function.

Code: 601

Description: ADF Door was opened during ADF transmission.
Causes:

Code: 623

Description: No original was in the ADF. (Builtin dialer engaged)
Causes: Operator removed the original from the ADF after dialing was completed. Original was not set properly in the ADF.

Code: 630

Description: Redial count over.
Causes: No dial tone detected. Sensor dial tone is not detected. (destination dependent) Busy tone is detected. (destination dependent) T1 timer (35±5 sec.) elapsed without a signal from the receiver.