Description: Sorter: Staple unit motor error - Timing & Condition - The staple unit H.P. sensor does not activates within the timing programmed. When this error detected twice, this SC code is displayed.
Causes: • Poor connection of connectors. • Defective staple unit H.P. sensor • Defective grip shift motor • Defective main board
Remedy: 1. Check if the connectors of the staple unit H.P. sensor and/or staple unit motor are properly connected. 2. Replace the staple unit motor H.P. sensor. (Input check: SP 5-803-130) 3. Replace the staple unit motor. (Output check: SP 5- 804-128) 4. Replace the main board.
Description: LCT: Tray lift error - Timing & Condition - • The upper limit sensor does not activate within 18 seconds after the lift motor turns on (in UP direction) when the main switch is turned on or close the LCT cover. • The lower limit sensor does not activate within 18 seconds after the lift motor turns on (in DOWN direction) when paper runs out (paper end) or the Down key is pressed.
Causes: • Poor connection of connectors • Defective lift motor • Defective upper limit sensor • Defective pick-up solenoid • Defective LCT main board
Remedy: 1. Check if the connectors of the lift motor, upper limit sensor, and pick-up solenoid are properly connected. 2. Replace the lift motor. 3. Replace the upper limit sensor. 4. Replace the pick-up solenoid. 5. Replace the LCT main board
Description: FPU: Projector lamp overheated - Timing & Condition - The projector lamp overheats during projector operation.
Causes: • Poor connection of connector • Defective thermistor • Defective projector main board
Remedy: 1. Check if the connector of the fan is properly connected. 2. Replace the fan if it is defective. 3. Replace the thermistor if it is defective. 4. Replace projector main board.
Description: Upper total counter error (Black) - Timing & Condition - • Feedback signal stays LOW when the main switch is turned on. • Feedback signal stays LOW just before the trigger signal goes ON. • Feedback signal stays HIGH just before the trigger signal goes OFF.
Causes: • Poor connection of the connectors • Defective counter
Remedy: Check if the connectors are properly set. Replace the total counter. [ Signal Check ] Trigger line: CN230-B8 on I/O control board Counter OK signal: TP227 on I/O control Board
Description: Lower total counter error (Color) Timing & Condition - • Feedback signal stays LOW when the main switch is turned on. • Feedback signal stays LOW just before the trigger signal goes ON. • Feedback signal stays HIGH just before the trigger signal goes OFF.
Causes: • Poor connection of the connectors • Defective counter
Remedy: Check if the connectors are properly set. Replace the total counter. [ Signal Check ] Trigger line: CN230-B10 on I/O control board Counter OK signal: TP228 on I/O control board
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.