Description: Communication error between BICU and MCU
The BICU cannot communicate with the MCU board properly.
Causes: • Poor connection between the BICU and MCU • MCU defective • BICU defective
Code: SC602
Description: Communication error between BICU and HDD controller
The BICU cannot communicate with the HDD controller properly.
Causes: • Poor connection between the BICU board and HDD control board • BICU board defective
Code: SC620
Description: Communication error between BICU and ADF 1
The TXD and RXD signals between BICU and ADF main board do not stabilize.
Causes: • Poor connection between the BICU board and ADF main board • Noise on interface cable
Code: SC621
Description: Communication error between BICU and ADF 2
The TXD and RXD signals between BICU and ADF main board do not stabilize.
Causes: • Poor connection between the BICU board and ADF main board • ADF main board defective • BICU board defective
Code: SC622
Description: Communication error between BICU and ADF 3
Software error after abnormal user operation.
Causes: • Software error
Code: SC625
Description: Communication error between BICU and finisher 1
The acknowledge signal does not come back from the finisher or mailbox to the BICU board 3 times consecutively.
Causes: • Finisher or mailbox main board defective • BICU board defective • Poor connection between BICU board and finisher or mailbox main board • Noise on the interface cable
Code: SC626
Description: Communication error between BICU and finisher 2
The BICU board receives a low signal even when the communication line is connected between the BICU board and the finisher or mailbox.
Causes: • Finisher or mailbox main board defective • BICU board defective • Poor connection between BICU board and finisher or mailbox main board • Noise on the interface cable • Finisher or mailbox is installed with B098
Code: SC630
Description: CSS (RSS) communication error between line adapter and CSS center
Japan only