Các lỗi thường gặp

Code :
  • Code: 500
  • Description: Main motor lock error
    Failed to detect main motor lock signal for 7 checks in succession (total of 700ms) after main motor started to rotate, or after last lock signal was detected.
  • Causes: • Main motor defective • Too much load on the drive mechanism • Motor driver damaged
  • Code: 541
  • Description: Fusing thermistor open
    Thermistor generated abnormal values immediately after 24V power on.
  • Causes: • Fusing thermistor defective or disconnected • Fusing lamp defective • Fuse blown • PSU defective • Bad connection between fuser and machine
  • Code: 542
  • Description: Fusing temperature warm-up error
    During fusing warm-up, fusing temperature failed to reach target range within 22 seconds (when starting at least 25°C below the target temperature).
  • Causes: • Fusing thermistor defective • Fusing lamp defective • Thermofuse blown • PSU defective • Bad connection between fuser and machine
  • Code: 543
  • Description: Fusing overheat error
    Detected fusing temperature remained above 230°C for 1 second.
  • Causes: • Fusing thermistor defective • PSU defective
  • Code: 544
  • Description: Fusing low temperature error
    Detected fusing temperature remained abnormally low for 1 second during fusing operation (below 140°C) or during standby mode.
  • Causes: • Fusing thermistor defective • PSU defective • Bad connection between fuser and machine
  • Code: 546
  • Description: Unstable fusing temperatureDetected that fusing temperature changed more than +-25°C/second two seconds in succession.
  • Causes: • Fusing thermistor defective • PSU defective • Bad connection between fuser and machine
  • Code: 547
  • Description: Zero-cross detection error
    Detection error (detection overflow or busy) occurred 8 times in succession (at 20-ms intervals) while 24V power was on.
  • Causes: • PSU defective • FCU defective
  • Code: 548
  • Description: Fusing-temperature range violation (too high)
    During paper transport, fusing temperature moved above limit (200°C for plain paper, 210°C for thick paper) and remained above limit for 10 seconds.
  • Causes: • TRIAC short • Fan not running