Các lỗi thường gặp

Code :
  • Code: 544
  • Description: Fusing overheat error (hardware circuit detection)
    The dual monitoring circuitry of the BICU detects extremely high temperature and tripped the relay circuit off.
  • Causes: • Power supply unit defective • I/O board (IOB) defective • BICU defective • Fusing thermistor defective
  • Code: 545
  • Description: Fusing lamp remains on
    After warm-up the fusing lamp remains at full power for 10 seconds without the hot roller rotating.
  • Causes: • Thermistor is out of position.
  • Code: 546
  • Description: Fusing ready temperature unstable
    The fusing temperature is fluctuating.
  • Causes: • Thermistor connection loose • Fusing unit connector loose
  • Code: 547
  • Description: Zero cross signal malfunction
    The applied power supply ac frequency was detected at over 66Hz or below 45Hz, and the zero cross signals are not detected within a certain period within 500 ms after the main power switch has been turned on.
  • Causes: • Power supply board defective • Noise on the ac power line
  • Code: 548
  • Description: Fusing unit installation error
    The machine cannot detect the fusing unit when the front cover and right cover are closed.
  • Causes: • Fusing unit is not installed • Fusing unit connection loose
  • Code: 599
  • Description: 1-bin tray motor lock (optional 1-bin tray unit)
    A 1-bin tray motor lock signal is not detected for more than 300 ms during rotation.
  • Causes: • 1-bin tray motor locked from overload • 1-bin tray motor defective • 1-bin tray motor connection loose
  • Code: 601
  • Description: Communication error between BICU and scanner unit
    Within 800 ms after power on, after 3 attempts the BICU does not communicate with the SIB via the serial line.
  • Causes: • Serial line connecting the BICU and SIB defective • External noise on the serial line • SIB board defective • BICU board defective
  • Code: 610
  • Description: Communication timeout error between BICU and ADF
    The BICU cannot receive a response within 100 ms after 3 attempts after sending data to the ARDF.
  • Causes: • BICU board and ADF main board serial line connection defective • External noise • ADF main board defective • BICU board defective