Description: Print image data transfer error
The image transfer from the controller to the engine via the PCI bus does not end within 15 s after starting.
Causes: • Controller board defective • BICU defective • Connectors between BICU and controller loose or defective
Description: Scanner image data transfer error
The image transfer from the engine to the controller via the PCI bus does not end within 3 s after starting.
Causes: • Controller board defective • BICU defective • Connectors between BICU and controller loose or defective • SIB defective
Description: Software write parameter setting error
An unstable area at the storage destination in the settings table is set NULL for the parameter received by the write module.
Description: Software performance error
The software attempted to perform an unexpected operation.
Causes: • Software defective • Internal parameter incorrect • Insufficient working memory • When this SC occurs, the file name, address, and data will be stored in NVRAM. This information can be checked by using SP7-403. Note the above data and the situation in which this SC occurs. Then report the data and conditions to your technical control center.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.