Description: BICU - ADF communication/timeout error
After 1 data frame is sent to the finisher MBX, an ACK signal is not received within 100 ms, and is not received after 3 retries.
Causes: • Serial line connection unstable
• External noise on the line
Description: BICU - Finisher communication/break error
During communication with the finisher MBX, the BICU received a break (Low) signal from the finisher.
Causes: • Serial line connection unstable
• External noise on the line
Description: BICU - Tray 1~4 communication/timeout error
After 1 data frame is sent to the trays, an ACK signal is not received within 100 ms, and is not received after 3 retries.
Causes: • Serial line connection unstable
• External noise on the line
Description: BICU - LCT communication/timeout error
After 1 data frame is sent to the LCT, an ACK signal is not received within 100 ms, and is not received after 3 retries.
Causes: • Serial line connection unstable
• External noise on the line