Các lỗi thường gặp

Code :
  • Code: 542
  • Description: Fusing temperature warm-up error
    One of the following occurred:
    • After power on, or after closing the front door, the hot roller does not reach the 100°C control temperature within 25 s.
    • 5 sec. after temperature rise started, temperature remained below 21°C after 5 samplings.
    • Fusing unit did not attain reload temperature within 48 sec. of the start of fusing temperature control.
  • Causes: • Fusing lamp disconnected
    • Thermistor warped, out of position
    • Thermostat not operating
  • Code: 543
  • Description: Fusing lamp overheat error 1 (software)
    Central thermistor detected a temperature of 240°C at the center of the hot roller. Fusing temperature control software error
  • Causes: • PSU defective
    • IOB defective
    • BICU defective
  • Code: 544
  • Description: Fusing lamp overheat error 1 (hardware)
    The central thermistor or an end thermistor detected a temperature of 250°C on the hot roller.
  • Causes: • PSU defective
    • IOB defective
    • BICU defective
  • Code: 545
  • Description: Fusing lamp overheat error 2
    After hot roller reaches warmup temperature, the fusing lamps remained on at full capacity for 11 samplings (1.8 sec. duration) while the hot roller was not rotating.
  • Causes: • Thermistor damaged, or out of position
    • Fusing lamp disconnected
  • Code: 547
  • Description: Zero cross signal malfunction
    One of the following conditions is detected 10 times:
    • When the main switch is on, the frequency measured by the number of zero cross signals for 500 ms is larger than 66Hz or smaller than 45 Hz.
    • The interval between one zero cross signal and the next is 7.5 ms or shorter 3 times consecutively for 500 ms.
  • Causes: • Noise on the ac power line
  • Code: 550
  • Description: Fusing Web End
    Web end detected 5 times within 500 ms and web motor continues to rotate 40 s. If web end is detected for another 500 ms, then the SC is logged.
  • Causes: • Web end (requires replacement)
    • Web end sensor defective Note: After replacing the web with a new one, reset SP1902 001 to "0" to release SC550.
  • Code: 551
  • Description: Fusing thermistor error 1
    The end thermistor (contact type) was less than 0C (32F) for more than 7 seconds.
  • Causes: • Thermistor disconnected
    • Thermistor connector defective
  • Code: 552
  • Description: Fusing thermistor error 2
    The end thermistor (contact type) could not detect:
    • 100°C 25 seconds after the start of the warmup cycle.
    • A change in temperature more than than 16 degrees for 5 seconds.
    • The reload temperature with 56 seconds after the start of the fusing temperature control cycle.
  • Causes: • Fusing lamp disconnected
    • Thermistor bent, damaged
    • Thermistor position incorrect