Các lỗi thường gặp

Code :
  • Code: SC129
  • Description: Scanner motor speed control error
    The scanner speed is out of standard during scanning.
  • Causes: • Scanner motor defective • PSU defective • MCU defective • Scanner drive defective
  • Code: SC130
  • Description: SBU error
    When the main switch is turned on, the BICU cannot receive the correct signal from the SBU.
  • Causes: • SBU defective • BICU defective • Cable between SBU and BICU defective
  • Code: SC300
  • Description: Charge corona output error 1
    The feedback voltage from the charge corona unit is too high.
  • Causes: • Charge P.P. defective • Poor charge corona unit connection
  • Code: SC301
  • Description: Charge corona output error 2
    The control PWM for the charge corona unit is too high.
  • Causes: • Charge P.P. defective • Poor charge corona unit connection
  • Code: SC302
  • Description: Charge corona output error 3
    The control PWM for the charge grid is too high.
  • Causes: • Charge P.P. defective • Poor charge corona unit connection
  • Code: SC303
  • Description: Charge corona output error 4
    The feedback voltage from the charge grid is too high.
  • Causes: • Charge P.P. defective • Poor charge corona unit connection
  • Code: SC305
  • Description: Charge corona wire cleaner error 1
    The charge corona wire cleaner does not return to its home position.
  • Causes: • Charge corona wire cleaner motor defective • Charge P.P. defective • IOB defective
  • Code: SC306
  • Description: Charge corona wire cleaner error 2
    The charge corona wire cleaner motor connector is not connected.
  • Causes: • The charge corona wire cleaner motor connector is not connected.