Các lỗi thường gặp

Code :
  • Code: 101
  • Description: Exposure Lamp Error
    The standard white level was not detected properly when scanning the white plate
  • Causes: • Exposure lamp defective• Exposure lamp stabilizer defective • Exposure lamp connector defective • Dirty scanner mirror or scanner mirror out of position • SBU board defective • SBU connector defective • Lens block out of position • Incorrect position or width of white plate scanning
  • Code: 120
  • Description: Scanner home position error 1
    The scanner home position sensor does not detect the off condition during initialization or copying.
  • Causes: • Scanner home position sensor defective • Scanner drive motor defective • Scanner home position sensor connector defective • Scanner drive motor connector defective • IOB board defective
  • Code: 121
  • Description: Scanner home position error 2
    The scanner home position sensor does not detect the on condition during initialization or copying.
  • Causes: • Scanner home position sensor defective • Scanner drive motor defective • Scanner home position sensor connector defective • Scanner drive motor connector defective • IOB board defective
  • Code: 122
  • Description: Scanner home position error 3
    The scanner home position sensor detects the on condition while the scanner is returning to the home position.
  • Causes: • Scanner home position sensor defective • Scanner drive motor defective • Scanner home position sensor connector defective • Scanner drive motor connector defective • IOB board defective
  • Code: 123
  • Description: Scanner home position error 4
    The scanner home position sensor does not detect the on condition after the scanner returns to the home position.
  • Causes: • Scanner home position sensor defective • Scanner drive motor defective • Scanner home position sensor connector defective • Scanner drive motor connector defective • IOB board defective
  • Code: 130
  • Description: Communication Error between BiCU and SBU
    The BiCU board cannot detect the SBU connect signal.
  • Causes: • The flat cable between the BiCU board and the SBU has a poor connection • The flat cable between the BiCU board and the SBU damaged • BiCU board defective • SBU defectiv
  • Code: 192
  • Description: Automatic SBU adjustment error
    During the automatic SBU adjustment, the machine detects that the white level read from the white plate or paper is out of range.
  • Causes: • Exposure lamp defective • SBU auto adjustment was not done correctly • SBU defective • BiCU board defective • Exposure lamp stabilizer defective
  • Code: 194
  • Description: SBU White Level Detection Error
    The automatic SBU adjustment failed twenty times consecutively.
  • Causes: • Exposure lamp defective • Dirty white plate • Incorrect position or width of white plate scanning • BiCU board defective • SBU board defective