Code :
  • Code: 900
  • Description: Electrical total counter error
    The electrical total counter does not work properly.
  • Causes: • NVRAM defective
  • Code: 901
  • Description: Mechanical total counter
    The mechanical total counter does not work properly.
  • Causes: • Mechanical total counter defective • IOB defective • Disconnected mechanical total counter
  • Code: 921
  • Description: IMB memory controller error
    A memory control job is not completed within a certain period.
  • Causes: • IMB defective • BiCU defective • Poor connection between IMB and BiCU
  • Code: 922
  • Description: IMB DRAM error
    The machine detects a discrepancy in the IMB DRAM write/read data during its write/read test (done at power off/on and at recovery from low power or night/off mode).
  • Causes: • IMB defective • BiCU defective • Poor connection between BiCU and IMB
  • Code: 924
  • Description: Optional DRAM error
    The machine detects a discrepancy in the Optional DRAM write/read data during its write/read test (done at power off/on and at recovery from low power or night/off mode).
  • Causes: • Non-supported DRAM connected • Poor connection between IMB and optional DRAM • Optional DRAM defective • IMB defective • BiCU defective
  • Code: 925
  • Description: IMB non-connected error
    IMB is not connected. This SC only appears with B040 and B043 version machines.
  • Causes: • IMB is not connected • Poor connection between BiCU and IMB • IMB defective • BiCU defective
  • Code: 926
  • Description: Memory capacity error
    The machine detects a discrepancy between the memory capacity detected during the memory check at power on and the check at recovery from low power or night/off mode.
  • Causes: • Poor connection between optional DRAM and IMB • Optional DRAM defective • IMB defective • BiCU defective
  • Code: 981
  • Description: NVRAM error
    The machine detects a discrepancy in the NVRAM write/read data when attempting to save actual data to the NVRAM (i.e. during actual use).
  • Causes: • NVRAM defective • Poor connection between BiCU and NVRAM • NVRAM is not connected • BiCU defective