Các lỗi thường gặp

Code :
  • Code: 553
  • Description: Overheat error (pressure roller)
    The pressure roller thermistor detects 165°C for 5 seconds.
  • Causes: • Loose connection • Defective BICU board • Defective PSU
  • Code: 554
  • Description: Low temperature error (pressure roller)
    During standby or operation, the pressure roller thermistor detects 60°C or less for 5 seconds.
  • Causes: • Defective lamp (loose connection, thermostat failure, PSU, thermostat) • Incorrect detection (thermistor loose connection, fusing - drawer loose connection)
  • Code: 555
  • Description: Full power error (pressure roller)
    Fusing unit warm-up is complete.→ The fusing pressure roller stops turning. → The pressure roller lamp keeps outputting the maximum power for 200 seconds.
  • Causes: • Thermistor loose connection • Fusing - drawer loose connection
  • Code: 556
  • Description: Unstable temperature (pressure roller)
    The pressure roller thermistor detects unstable temperature increases or decreases within 60 seconds.
  • Causes: • Thermistor loose connection • Fusing - drawer loose connection
  • Code: 560
  • Description: Zero cross error
    The main switch is turned on; the fusing relay turns on. → 50 Hz or 60 Hz is not detected within 5 seconds.
  • Causes: • Defective PSU • Incorrect power supply
  • Code: 570
  • Description: Fusing oil end
    500 sheets of paper have been output since oil end was detected.
  • Causes: • Insufficient oil (the oil tank in the rear of the machine) • Defective oil pipe • Defective oil pump • Defective oil end sensor
  • Code: 571
  • Description: Fusing oil overflow
    • The oil overflow sensor detects oil. • When the machine covers are closed, the oil supply unit is not detected. • When the machine covers are closed, the fusing unit is not detected.
  • Causes: • Defective oil end sensor • Defective oil overflow sensor • Defective sensor cable • Oil supply unit not installed
  • Code: 620
  • Description: ADF communication error
    The ADF has been detected. → A communication error has occurred.
  • Causes: • Loose connection • Defective ADF • Defective BICU board • Defective scanner I/O board • External noise