Description: ID sensor error
The ID sensor is being calibrated (process control, step 1) → While the LED is off, the output voltage is 0.5 V or lower.
Causes: • Defective ID sensor • Defective connector
Code: 481
Description: Transfer belt mark detection error
• The main motor is operating; and the lock signal is detected. → The belt mark sensor signal does not change for 120 milliseconds.
Causes: • Defective main motor • Image transfer belt out of position • Belt mark blurred or absent
Code: 503
Description: 3rd tray error
• The tray lift motor turns on. → The top of the paper stack is not detected for 18 seconds. • The tray is set. → The top of the paper stack is detected. → The bottom plate is lowered. → The stack detection is not cleared within 7 seconds. → These steps are repeated 4 times.
Causes: • Defective paper height sensor • Defective tray lift motor
Code: 504
Description: 4th tray error
• The tray lift motor turns on. → The top of the paper stack is not detected for 18 seconds. • The tray is set. → The top of the paper stack is detected. → The bottom plate is lowered. → The stack detection is not cleared within 7 seconds. → These steps are repeated 4 times.
Causes: • Defective paper height sensor • Defective tray lift motor
Code: 515
Description: Duplex unit communication error
• A connection error occurs. • The signal is sent from the copier to the duplex unit every 3 seconds while paper is not transported by the unit. However, the duplex unit does not respond within 5 seconds.
Causes: • Defective duplex unit board • Defective BICU • Defective Ex-IOB • Defective connection (Main unit Duplex unit)
Code: 520
Description: Fusing unit motor
• The motor starts or changes speed. → The lock signal does not continue for 1 second within a 3second interval. • The motor starts. → The lock signal is detected and operation proceeds normally. → The lock signal is interrupted for 1 second.
Causes: • Defective fusing unit motor
Code: 521
Description: Paper feed motor error
• The motor starts or changes speed. → The lock signal does not continue for 1 second within a 3second interval. • The motor starts. → The lock signal is detected and operation proceeds normally. → The lock signal is interrupted for 1 second.