Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Ricoh Aficio 150 — Trang 4/8

Code: SC507

Description: Tandem tray lift error (optional LCT)
The lower limit sensor is not activated after the paper tray lift motor has been on to lower the tandem tray for 8 seconds.
Causes: • Paper tray lift motor defective • Lower limit sensor defective • Too much load on the drive mechanism

Code: SC508

Description: Rear fence drive error (optional LCT)
The return position sensor is not activated after the rear fence drive motor has been on to lower the tandem tray for 8 seconds.
Causes: • Rear fence motor defective • Return position sensor defective • Too much load on the drive mechanism

Code: SC509

Description: Side fence drive error (optional LCT)
The side fence positioning sensor is not activated for more 3 seconds when the paper stack in the left tray is moved to the right tray. The side fence close sensor is not activated for more 3 seconds after moving the paper stack to the right tray.
Causes: • Side fence motor defective • Side fence position sensor defective • Side fence close sensor defective • Too much load on the drive mechanism

Code: SC541

Description: Fusing thermistor open
The fusing temperature detected by the thermistor was below 55 °C for 15 seconds or below 75 °C for 20 seconds.
Causes: • Fusing thermistor defective or out of position • Fusing lamp open • Fusing thermofuse open • Power supply board defective • Poor connection of the fusing unit

Code: SC542

Description: Fusing temperature warm-up error
The fusing temperature does not reach 155 °C within 60 seconds after the main switch is turned on.
Causes: • Fusing thermistor defective or out of position • Fusing lamp open • Fusing thermofuse open • Power supply board defective • Poor connection of the fusing unit

Code: SC543

Description: Fusing overheat error
A fusing temperature of over 231°C is detected for 1 second by the fusing thermistor.
Causes: • Fusing thermistor defective • Power supply board defectivee mechanism

Code: SC544

Description: Fusing low temperature error
A fusing temperature of lower than 100°C is detected for 1 second by the fusing thermistor.
Causes: • Fusing thermistor defective • Power supply board defective • Poor connection of the fusing unit

Code: SC546

Description: Unstable fusing temperature
Fusing temperature more than 60 °C: The fusing temperature does not rise 2°C or more within 6 seconds after the fusing lamp has been on. Fusing temperature 60 °C or less: The fusing temperature does not rise 2°C or more during a 6 second interval (the 6 s timer starts 14 s after the fusing lamp turned on).
Causes: • Thermistor defective • Poor connection of the fusing unit • Power supply unit defective