Các lỗi thường gặp

Code :
  • Code: 730
  • Description: Finisher stapler motor error (1000-sheet finisher)
    The stapler does not return to its home position within a certain time after the stapler motor turned on. The stapler H.P sensor does not activate within a certain time after the stapler motor turned on.
  • Causes: • Stapler motor defective • Stapler H.P sensor defective • Poor stapler motor connection
  • Code: 731
  • Description: Output tray motor error (500-sheet finisher) Exit guide plate motor error (1000-sheet finisher)
    The tray upper limit sensor does not activate within a certain time after the shift motor turned on. (500-sheet finisher) The exit guide plate open sensor or exit guide plate HP sensor does not activate within a certain time after the exit guide plate motor turned on. (1000-sheet finisher)
  • Causes: 500-sheet finisher • Output tray motor defective • Tray upper limit sensor defective 1000-sheet finisher • Exit guide plate motor defective • Exit guide plate HP sensor defective • Exit guide plate open sensor defective
  • Code: 732
  • Description: Finisher shift motor error (1000-sheet finisher)
    Roller shift does not finish within a certain time after the shift motor turned on.
  • Causes: • Shift motor defective • Shift tray HP sensor defective
  • Code: 770
  • Description: Shift tray shift motor error
    During a shift operation the sensor state did not change (off to on, or on to off) within 2.4 sec.
  • Causes: • Shift sensor defective • Shift motor defective
  • Code: 791
  • Description: Bridge communication error
    The SBCU cannot communicate with the bridge unit properly when the finisher is installed.
  • Causes: • Poor connection between the main machine and bridge unit • SBCU board defective
  • Code: 792
  • Description: Finisher connection error
    The SBCU cannot communicate with the finisher properly when the bridge unit is installed.
  • Causes: • Poor connection between the finisher and bridge unit • SBCU board defective
  • Code: 793
  • Description: Interchange communication error
    The SBCU cannot communicate with the interchange unit properly when the duplex unit is installed.
  • Causes: • Poor connection between the interchange unit and main machine • SBCU board defective
  • Code: 800
  • Description: Startup without video output end error (K)
    Video transfer to the engine is started, but the engine did not issue a video transmission end command within the specified time.
  • Causes: Controller board defective