Mã lỗi Ricoh Aficio 2035e — Trang 17/18

Code: 985

Description: Scanner image data transfer error
The image transfer from the engine to the controller via the PCI bus does not end within 3 s after starting.
Causes: • Controller board defective • BICU defective • Connectors between BICU and controller loose or defective • SIB defective

Code: 986

Description: Software write parameter setting error
An unstable area at the storage destination in the settings table is set NULL for the parameter received by the write module.
Causes: • Software defective

Code: 990

Description: Software performance error
The software attempted to perform an unexpected operation.
Causes: • Software defective • Internal parameter incorrect • Insufficient working memory • When this SC occurs, the file name, address, and data will be stored in NVRAM. This information can be checked by using SP7-403. Note the above data and the situation in which this SC occurs. Then report the data and conditions to your technical control center.

Code: 991

Description: Software continuity error
The software attempted to perform and unexpected operation. However, unlike SC990, the object of the error is continuity of the software.
Causes: • Software bug • Internal parameter incorrect • Insufficient working memory

Code: 992

Description: Unexpected Software Error
Software encountered an unexpected operation not defined under any SC code.
Causes: • Software defective • An error undetectable by any other SC code occurred

Code: 995

Description: Machine Type Information Error
After the machine is powered on, a mismatch is detected between the CPM information sent from the controller to the engine and the CPM information specified by the DIP SW settings.
Causes: The B079 (35 cpm) and B082 (45 cpm) use the same controller board, but the DIP SW settings must be set correctly for the machine speed.

Code: 996

Description: FCU board error
FCU board is connected but not ready.
Causes: • FCU board defective and requires replacement • Firmware incorrect

Code: 997

Description: Application function selection error
The application selected by a key press on operation panel does not start or ends abnormally.
Causes: • Software defective • An option required by the application (RAM, DIMM, board) is not installed