Description: Zero cross signal malfunction
The applied power supply ac frequency was detected at over 66Hz or below 45Hz, and the zero cross signals are not detected within a certain period within 500 ms after the main power switch has been turned on.
Causes: • Power supply board defective • Noise on the ac power line
Description: Communication error between BICU and scanner unit
Within 800 ms after power on, after 3 attempts the BICU does not communicate with the SIB via the serial line.
Causes: • Serial line connecting the BICU and SIB defective • External noise on the serial line • SIB board defective • BICU board defective
Description: Communication timeout error between BICU and ADF
The BICU cannot receive a response within 100 ms after 3 attempts after sending data to the ARDF.
Causes: • BICU board and ADF main board serial line connection defective • External noise • ADF main board defective • BICU board defective