Description: Fusing ready temperature unstable
The fusing temperature is fluctuating.
Causes: • Thermistor connection loose • Fusing unit connector loose
Code: 547
Description: Zero cross signal malfunction
The applied power supply ac frequency was detected at over 66Hz or below 45Hz, and the zero cross signals are not detected within a certain period within 500 ms after the main power switch has been turned on.
Causes: • Power supply board defective • Noise on the ac power line
Code: 548
Description: Fusing unit installation error
The machine cannot detect the fusing unit when the front cover and right cover are closed.
Causes: • Fusing unit is not installed • Fusing unit connection loose
Code: 599
Description: 1-bin tray motor lock (optional 1-bin tray unit)
A 1-bin tray motor lock signal is not detected for more than 300 ms during rotation.
Causes: • 1-bin tray motor locked from overload • 1-bin tray motor defective • 1-bin tray motor connection loose
Code: 601
Description: Communication error between BICU and scanner unit
Within 800 ms after power on, after 3 attempts the BICU does not communicate with the SIB via the serial line.
Causes: • Serial line connecting the BICU and SIB defective • External noise on the serial line • SIB board defective • BICU board defective
Code: 610
Description: Communication timeout error between BICU and ADF
The BICU cannot receive a response within 100 ms after 3 attempts after sending data to the ARDF.
Causes: • BICU board and ADF main board serial line connection defective • External noise • ADF main board defective • BICU board defective
Code: 611
Description: Communication break error between BICU and ADF
The BICU receives a break signal from the ADF main board.
Causes: • Serial line connecting BICU and ADF unstable • External noise • ADF main board defective • BICU board defective
Code: 612
Description: Communication command error between BICU and ADF
The BICU sends a command to the ADF main board that it cannot execute.
Causes: • Abnormal operation performed by software