Description: Software error 2
The software performs an unexpected function and the program cannot continue.
Causes: • Software defective, re-boot
Code: 991
Description: Software error 3
The software performs an unexpected function and the program cannot continue. However, unlike SC990, recovery processing allows the program to continue.
Causes: Software defective, re-boot
Code: 992
Description: Software error 4: Undefined
An error not controlled by the system occurred (the error does not come under any other SC code).
Causes: • Software defective
• Turn the machine power off and on. The machine cannot be used until this error is cleared.
Code: 994
Description: Operation Panel Management Records Exceeded
An error occurred because the number of records exceeded the limit for images managed in the service layer of the firmware. This can occur if there if there are too many application screens open on the operation panel.
Causes: • No action required because this SC does not interfere with operation of the machine
Code: 997
Description: Cannot select application function
An application does not start after the user pushed the correct key on the operation panel.
Causes: • Software bug
• A RAM or DIMM option necessary for the application is not installed or not installed correctly.
Code: 998
Description: Application cannot start
Register processing does not operate for an application within 60 s after the machine power is turned on. No applications not start correctly, and all end abnormally.
Causes: • Software bug
• A RAM or DIMM option necessary for the application is not installed or not installed correctly