Code :
- Code: 620
- Description: ARDF communication error
• After the ARDF is detected, the break signal occurs or communication timeout occurs.
- Causes: • Incorrect installation of ARDF • ARDF defective • IPU board defective • External noise
- Code: 621
- Description: Two-tray finisher/booklet finisher communication error
- Causes: • Cable problems • BCU problems • PSU problems in the machine • Main board problems in the peripherals
- Code: 622
- Description: Bank communication error
- Causes: • Cable problems • BCU problems • PSU problems in the machine • Main board problems in the peripherals
- Code: 623
- Description: Duplex unit communication error
- Causes: • Cable problems • BCU problems • PSU problems in the machine • Duplex control board problem
- Code: 630
- Description: CSS communication error
- Causes: • Communication line error
- Code: 632
- Description: MF accounting device error 1
- Causes: • Loose connection between the controller and the accounting device
- Code: 633
- Description: MF accounting device error 2
- Causes: • Loose connection between the controller and the accounting device
- Code: 634
- Description: MF accounting device error 3
- Causes: • Defective controller of the MF accounting device • Battery error