Description: Potential sensor error 3: Vr C
Vr > 200V The residual voltage (Vr), the amount of voltage that remains on the surface of the drum after the QL fires is greater than 200V.
Description: Potential sensor error 4: Vr Y
Vr > 200V The residual voltage (Vr), the amount of voltage that remains on the surface of the drum after the QL fires is greater than 200V.
Description: Potential sensor error 5: Vd K
The VdHome reading, the first step of the process control self-check, detected that the development potential of the unexposed areas of the drum are not within the prescribed range (-500 to -700)
Description: Potential sensor error 6: Vd M
The VdHome reading, the first step of the process control self-check, detected that the development potential of the unexposed areas of the drum are not within the prescribed range (-500 to -700)
Description: Potential sensor error 7: Vd C
The VdHome reading, the first step of the process control self-check, detected that the development potential of the unexposed areas of the drum are not within the prescribed range (-500 to -700)
Description: Potential sensor error 8: Vd Y
The VdHome reading, the first step of the process control self-check, detected that the development potential of the unexposed areas of the drum are not within the prescribed range (-500 to -700)
Description: Image transfer power pack error 1: K
An interrupt checks the status of the power pack every 2 ms. This SCis issued if the BCU detects a short in the power pack for K, M, C, or Y 250 times within 500 ms.
Causes: • Transfer belt damaged, insulation damaged • Insulation on high voltage cable damaged • Another hot point inside the machine has damaged insulation • Insulation around high-voltage power supply damaged • IOB damaged
Description: Image transfer power pack error 2: M
An interrupt checks the status of the power pack every 2 ms. This SCis issued if the BCU detects a short in the power pack for K, M, C, or Y 250 times within 500 ms.
Causes: • Transfer belt damaged, insulation damaged • Insulation on high voltage cable damaged • Another hot point inside the machine has damaged insulation • Insulation around high-voltage power supply damaged • IOB damaged
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.